| dc.contributor.advisor | Ambrósio Júnior, Renato | |
| dc.contributor.author | Costa Neto, Alexandre Batista da | |
| dc.date.accessioned | 2026-10-28T18:27:37Z | |
| dc.date.available | 2026-10-28T18:27:37Z | |
| dc.date.issued | 2024-09-30 | |
| dc.identifier.citation | COSTA NETO, Alexandre Batista da. Variabilidade da distância vértice posterior do refrator Vision-STM 700 (Essilor) em uma população normal. 2024. 65 f. Dissertação (Mestrado em Medicina) – Universidade Federal do Estado do Rio de Janeiro, Rio de Janeiro, 2024. | pt_BR |
| dc.identifier.uri | http://hdl.handle.net/unirio/15483 | |
| dc.description.sponsorship | n/a | pt_BR |
| dc.language.iso | Portuguese | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.title | Variabilidade da distância vértice posterior do refrator Vision-STM 700 (Essilor) em uma população normal | pt_BR |
| dc.title.alternative | Variability of the posterior vertex distance of the Vision-STM 700 refractor (Essilor) in a normal population | pt_BR |
| dc.type | masterThesis | pt_BR |
| dc.contributor.referee | Ambrósio Júnior, Renato | |
| dc.contributor.referee | Colombini, Giovanni Nicola Umberto Italiano | |
| dc.contributor.referee | Haddad, Jorge | |
| dc.degree.department | CCBS | pt_BR |
| dc.degree.grantor | Universidade Federal do Estado do Rio de Janeiro - UNIRIO | pt_BR |
| dc.degree.level | Mestrado Profissional | pt_BR |
| dc.degree.local | Rio de Janeiro, RJ | pt_BR |
| dc.degree.program | Programa de Pós-Graduação em Medicina | pt_BR |
| dc.subject.cnpq | CIÊNCIAS DA SAÚDE | pt_BR |
| dc.subject.cnpq | MEDICINA | pt_BR |
| dc.subject.en | Ocular refraction | pt_BR |
| dc.subject.en | Refractive errors | pt_BR |
| dc.subject.en | Refratometry | pt_BR |
| dc.subject.en | Refractive surgical procedures | pt_BR |
| dc.subject.en | Back vertex distance | pt_BR |
| dc.description.abstracten | Objective: Studying the variability of the back vertex distance according to forehead adjustment and estimating its impact on manifest refraction. Methods: Prospective study was carried out in a private clinic. Refraction was performed using the Vision-S 700 (Essilor) with five pre-established forehead adjustment positions. Results: From de analysis of 52 eyes (in 26 patients), it was found that the average back vertex distance in the third pre-established forehead position in the right eye was 12.25 mm (variation of 11.50 mm) and in left eye, 11.75 mm (variation of 12.00 mm). Conclusion: Back vertex distance in the refractor varies among patients and is influenced by forehead adjustment. Variations impact refraction accuracy. The suggestion is adjusting the forehead position to the third pre-established forehead adjustment position on the Vision-S if the refractor´s back vertex distance is not measured in all patients. | pt_BR |
| dc.degree.country | Brasil | pt_BR |
| dc.description.sponsordocumentnumber | n/a | pt_BR |
| dc.description.abstractpt | Objetivo: Estudar a variabilidade da distância vértice posterior, de acordo com o ajuste da testa e estimar seu impacto na refração manifesta. Métodos: Estudo prospectivo realizado em clínica privada. A refração foi realizada utilizando cinco posições preestabelecidas de ajustes de testa com o Vision-S 700 (Essilor). Resultados: A partir da análise de 52 olhos (em 26 pacientes), verificou-se que a média da distância vértice posterior na posição de testa preestabelecida 3 no olho direito foi de 12,25 mm (variação de 11,50 mm) e, no olho esquerdo, 11,75 mm (variação de 12,00 mm). Conclusão: A distância vértice posterior no refrator varia entre pacientes e está relacionada ao ajuste da testa. As variações afetam a precisão da refração. A sugestão é ajustar a posição da testa na terceira posição preestabelecida de ajuste de testa no Vision-S 700, caso a distância vértice posterior do refrator não seja medida em todos os pacientes. | pt_BR |
| dc.subject.pt | Refração ocular | pt_BR |
| dc.subject.pt | Erros de refração | pt_BR |
| dc.subject.pt | Refratometria | pt_BR |
| dc.subject.pt | Procedimentos cirúrgicos refrativos | pt_BR |
| dc.subject.pt | Distância vértice posterior | pt_BR |